메뉴 건너뛰기

이너포스

공지사항

    • 글자 크기

Effective Overload Protocols

ShelleyLuy525023481172025.05.15 21:33조회 수 2댓글 0

Avant-Garde Overcurrent Mitigation Strategies

Switched-mode power supplies contain a silicon-controlled rectifier an advanced semiconductor switch that can conduct high currents. The SCR is typically realized using a pair of bipolar junction transistors to act like a switch. Overcurrent conditions such as short circuits are a serious concern, as they can cause the semiconductor devices to overheat and degrade performance, and ultimately fail.


Polarity-reversing overcurrent protection is a prevalent and cost-effective methods used for protecting an SCR from overcurrent conditions. This is achieved by reversing the polarity of the SCR that exists between the power supply's terminals. To realize polarity-reversing overcurrent protection, two SCRs are required. The SCRs are turned on and off by a technique called an electronic control system.


Zener voltage regulator consists of a Zener diode and a BJT that function together to turn on and off the SCRs when the output of the power supply is in a fault state and reaches the threshold of the Zener diode voltage regulator. In terms of turn-off timing, there is little issue because the BJT in conjunction with the Zener diode turns off the SCR within 100 nanoseconds. However, to ensure that the output of the power supply is perfectly sinusoidal, the turn-off time of the SCR can affect this requirement. To avoid the negative impact, a push-pull topology is used.


Another overcurrent protection technique used in switched-mode power supplies is the parallel configuration of high power bipolar junction transistors to reduce currents efficiently. This configuration provides reliable protection by reducing the base current flow. This is achieved when a short-circuit fault occurs, and the fault current is split into the parallel-connected BJTs. The parallel BJTs continue to handle fault currents with lower base current by providing symmetrical fault current.


However, the drawback of this dual-path topology is the requirement of a current transformer that senses the fault current.


OCP can also be achieved using a separate OCP protection module. The protection module has a small transformer or a current transformer that measures the inrush current in one part of the power supply, then shuts down the system. These modules can be more affordable compared to Zener diode and BJT configurations and have higher efficiency. However, this type of module is larger in size.


In summary, the polarity-reversing overcurrent protection method is the most widely used in switched-mode power supplies due to its ease of implementation and اس اس آر low cost. It exploits the principle of electronic monitoring when the output is short-circuited to detect a fault condition. Other methods of overcurrent protection are the parallel configuration of BJTs and the OCP protection system. However, they can result in system instability and other reliability issues.

  • 0
  • 0
    • 글자 크기
ShelleyLuy52502348117 (비회원)

댓글 달기 WYSIWYG 사용

댓글 쓰기 권한이 없습니다.
정렬

검색

번호 제목 글쓴이 날짜 조회 수
251672 12 Helpful Tips For Doing Leveraging Advanced Manufacturing Methods... Miriam705882258292 2025.05.16 0
251671 Escorts In Australia LonTobey087199671 2025.05.16 0
251670 Exploring Haideh's Musical Journey AlmaNevarez1198926 2025.05.16 2
251669 Escorts In Australia Angelia59727601 2025.05.16 0
251668 Haideh: A Voice That Embodies Memories DominikFawcett907 2025.05.16 2
251667 Advanced Water Treatment Technologies In Use Margarita71U1875993 2025.05.16 2
251666 Сила Целебного Массажа: Экспертное Исследование По Уникальным Практикам Релаксации JanessaE0754168032941 2025.05.16 0
251665 Картонна Упаковка У Подарунках: Зручність, Екологічність і Стиль Camilla02891468666 2025.05.16 0
251664 Iran's Golden Age Of Iranian Music EIDAnitra04285089 2025.05.16 2
251663 Сила Профессионального Массажа: Всеобъемлющее Руководство По Разнообразным Техникам Релаксации JenniferMerrick77845 2025.05.16 0
251662 What You Should Have Asked Your Teachers About Stylish Drink Phone Covers CollinAlmond6104 2025.05.16 4
251661 Updating|Outdoor Lighting Trends For The {Season|This Time Of Year|Yearly Renewal| AmeliaJ70505930942352 2025.05.16 2
251660 Терапия Профессиональных Прикосновений: Экспертное Исследование По Уникальным Методикам Релаксации KathlenePatino3710954 2025.05.16 0
251659 3 Shortcuts For Coffee Phone Cases That Gets Your Result In Report Time LilaDundas729755887 2025.05.16 1
251658 The Benefits Of Exterior Lighting ChiBrody1765097954352 2025.05.16 2
251657 Искусство Гармонии Тела: Экспертное Исследование По Уникальным Методикам Релаксации OdellGardener42 2025.05.16 0
251656 Reps - The Conspriracy AntoineOmalley5 2025.05.16 0
251655 Protection For SSRs With Inductive Loads SherrylW9384864 2025.05.16 5
251654 Терапия Профессиональных Прикосновений: Экспертное Исследование По Эффективным Практикам Оздоровления Norma9483169288 2025.05.16 0
251653 Каким Образом Найти Оптимальное Криптовалютное Казино KristanWillie062503 2025.05.16 2
정렬

검색

위로