메뉴 건너뛰기

이너포스

공지사항

    • 글자 크기

Effective Overload Protocols

ShelleyLuy525023481172025.05.15 21:33조회 수 2댓글 0

Avant-Garde Overcurrent Mitigation Strategies

Switched-mode power supplies contain a silicon-controlled rectifier an advanced semiconductor switch that can conduct high currents. The SCR is typically realized using a pair of bipolar junction transistors to act like a switch. Overcurrent conditions such as short circuits are a serious concern, as they can cause the semiconductor devices to overheat and degrade performance, and ultimately fail.


Polarity-reversing overcurrent protection is a prevalent and cost-effective methods used for protecting an SCR from overcurrent conditions. This is achieved by reversing the polarity of the SCR that exists between the power supply's terminals. To realize polarity-reversing overcurrent protection, two SCRs are required. The SCRs are turned on and off by a technique called an electronic control system.


Zener voltage regulator consists of a Zener diode and a BJT that function together to turn on and off the SCRs when the output of the power supply is in a fault state and reaches the threshold of the Zener diode voltage regulator. In terms of turn-off timing, there is little issue because the BJT in conjunction with the Zener diode turns off the SCR within 100 nanoseconds. However, to ensure that the output of the power supply is perfectly sinusoidal, the turn-off time of the SCR can affect this requirement. To avoid the negative impact, a push-pull topology is used.


Another overcurrent protection technique used in switched-mode power supplies is the parallel configuration of high power bipolar junction transistors to reduce currents efficiently. This configuration provides reliable protection by reducing the base current flow. This is achieved when a short-circuit fault occurs, and the fault current is split into the parallel-connected BJTs. The parallel BJTs continue to handle fault currents with lower base current by providing symmetrical fault current.


However, the drawback of this dual-path topology is the requirement of a current transformer that senses the fault current.


OCP can also be achieved using a separate OCP protection module. The protection module has a small transformer or a current transformer that measures the inrush current in one part of the power supply, then shuts down the system. These modules can be more affordable compared to Zener diode and BJT configurations and have higher efficiency. However, this type of module is larger in size.


In summary, the polarity-reversing overcurrent protection method is the most widely used in switched-mode power supplies due to its ease of implementation and اس اس آر low cost. It exploits the principle of electronic monitoring when the output is short-circuited to detect a fault condition. Other methods of overcurrent protection are the parallel configuration of BJTs and the OCP protection system. However, they can result in system instability and other reliability issues.

  • 0
  • 0
    • 글자 크기
ShelleyLuy52502348117 (비회원)

댓글 달기 WYSIWYG 사용

댓글 쓰기 권한이 없습니다.
정렬

검색

번호 제목 글쓴이 날짜 조회 수
251197 Diyarbakır Escort - Diyarbakır Elden - Diyarbakır Ofis Escort MelvaBoase27185444 2025.05.15 0
251196 Щедрые Акции На Онлайн Казино Joy Casino Чтобы Увеличить Ваш Выигрыш RoryIpb7793212672375 2025.05.15 3
251195 Nikmati Koleksi Game Slot Gacor Dari Matador168 SiennaMcRoberts81777 2025.05.15 2
251194 Money Professional MillaFlower72754970 2025.05.15 2
251193 Biraz Düz Hayat Yaşadığınızı Mı Hissediyorsun? ArdisHaas18674096 2025.05.15 9
251192 10 Best Facebook Pages Of All Time About Home Service Businesses Focused On Air Quality Solutions... RodolfoBecker157 2025.05.15 0
251191 8 Go-To Resources About Home Service Businesses Focused On Air Quality Solutions... PrestonCandelaria9 2025.05.15 0
251190 Elazığ Escort Bayan Sitesi - Elazığ Escort Sayfası Wyatt76K65518286 2025.05.15 0
251189 Escorts In Australia LFVMirta73663140129 2025.05.15 0
251188 Diyarbakır Escort, Escort Diyarbakır Bayan, Escort Diyarbakır ArdisHaas18674096 2025.05.15 3
251187 Şehveti Müthiş Olan Diyarbakır Escort Bayan Meltem JustineBrower3368097 2025.05.15 0
251186 Ergani Escort, Ergani Bayan Escort AshleeBoniwell13 2025.05.15 2
251185 Escorts In Australia FRDJeannette622294 2025.05.15 0
251184 Терапия Прикосновений: Детальное Исследование По Разнообразным Техникам Релаксации MarinaVigil79263875 2025.05.15 0
251183 {{Подробный|Детальный|Полный|Всеобъемлющий|Тщательный} {Обзор|Анализ|Разбор|Отчет|Рейтинг} {Функций|Услуг|Бонусов|Игр|Предложений|Возможностей} {Казино|Онлайн Казино|Криптоказино|Крипто Казино|Интернет Казино} Банда} BelleMacy2042341 2025.05.15 7
251182 Gaziantep Escort Bayanların İlan Sayfası Wyatt76K65518286 2025.05.15 0
251181 ขั้นตอนการทดลองเล่น Co168 ฟรี Abbie87O120251014 2025.05.15 0
251180 How To Register On Cricbet99: A Step-by-Step Overview For Seamless Betting Miquel19370723840 2025.05.15 0
251179 การแนะนำค่ายเกม Co168 รวมถึงเนื้อหาและรายละเอียดต่าง ๆ จุดเริ่มต้นและประวัติ จุดเด่น ฟีเจอร์ที่น่าสนใจ และ ความน่าสนใจในทุกมิติ AnnisBillson922 2025.05.15 0
251178 Kalitesine Hayran Kalacağınız Diyarbakır Escort Bayan Zehra RockyKittredge569333 2025.05.15 0
정렬

검색

위로